Section 3.1: Measurements
3.1.1 Exterior door width ≥ 36 inches.
The width of each exterior door should be no less than 36" (91cm).
This applies to the width of the door itself. Doorways will often have less clearance when considering door jams and the door thickness, if on a hinge, when open.
3.1.2 Exterior door thresholds ≤ 0.5 inches.
The height of each exterior door threshold should be no more than 0.5" (1.25cm).
This includes bottom rails or tracks for sliding doors and other door hardware.
3.1.3 Landing area ≥ 5x5 feet.
The landing area's size outside each exterior door should be no less than 5×5' (60x60" or 152x152cm).
3.1.4 Landing area slope ≤ 1:50.
The landing area outside of each exterior door should slope no more than 1:50 (1.15º) in any direction.
Section 3.2: Features
3.2.1 No steps.
No steps should be required to access any entrance.
3.2.2 Covered landing area.
The landing area outside of each exterior door should be covered from the weather.
3.2.3 Shelf or space for a bench.
An outside shelf or space for a bench should be by the door.
If space for a bench is selected, ensure that the landing area still provides 5x5" (60x60" / 152x152cm) of maneuverable space, as indicated in 3.1.3.
3.2.4 Easily manipulated door hardware.
Door hardware should be operable with one hand while not requiring pinching or grasping.
3.2.5 Color contrasting door hardware.
The door hardware should clearly contrast against the door's color with a minimum contrast ratio of 3:1.
3.2.6 Electric door opener.
An electric door opener should be installed on at least one entrance door, ideally, the most commonly accessed by the primary entrance route from the parking area.
Exception:
This requirement may be met if the wiring and appropriate structural support allow easy installation. However, when working with smaller budgets, the electric door opener mechanism may be excluded. Please recognize that this is less ideal.
3.2.7 Evenly lit.
Lighting should be strategically placed to illuminate the doorway, landing area, and any hardware used to open or close the door.
Recommended: indirect and low lighting:
It is ideal to use indirect ambient lighting and low lighting that illuminates the landing area and doorway without visible bare bulbs or translucent covers (from a seated or standing position). Indirect lighting reduces eye strain and is more calming than direct lighting.
3.2.8 Automatic lighting activation.
Lights need to be able to be activated automatically.
3.2.9 Highly-visible numbers.
House or unit numbers should be in high contrast and easy to see from a distance at all times (night and day). They should be at least 4" (10cm) high.
3.2.10 Doorbell at the front door with audible and visual alerts.
A doorbell at the main entrance should be present, with alert(s) that can be heard and seen throughout the home. The doorbell switch should incorporate a light for easy visibility at night.
3.2.11 Two peepholes in the front door -or- sidelights at the front door.
There should be two peepholes (high and low) in the front door -or- sidelight windows at the front door.
Section 3.3: Storm Doors
3.3.1 No storm door.
Storm doors are not recommended for universal accessibility and should not be used unless required (see exception below).
Exception: local building code or HOA regulations
Suppose a locality or HOA requires a storm door, especially in regions that require extra protection against wind, rain, and other elements. In that case, a storm door may be used if its handle can be operated with one hand and does not require pressing a button to unlatch (e.g., with a lever handle). Additionally, the automatic closer should either be removed or located between 18-48" (46-122cm) from the landing area so someone can operate the hold-open feature with their hand vs. their foot.